logo logo
project-details

Heat Pump

A heat pump water heater (HPWH) operates on a simple yet efficient principle: it extracts heat from the surrounding air and uses it to heat water in a storage tank. Unlike traditional electric resistance water heaters, which generate heat directly, HPWHs transfer heat from one place to another, making them far more energy-efficient. This process involves a heat pump that uses a refrigerant to absorb heat from the air, which is then compressed to increase its temperature. The heated refrigerant releases its heat to the water in the tank through a heat exchanger. This method of heating water consumes less electricity, resulting in lower energy bills and reduced environmental impact. Installation of HPWHs is versatile, as they can be placed in various locations, such as basements, garages, or utility rooms, provided there is adequate space for air circulation. Overall, HPWHs offer a greener and more cost-effective solution for heating water in residential and commercial settings.

Inquiry Now

Air Source Heat Pump Water Heater (ASHPWH)

Running hot water, in recent times has become a necessity more than a luxury. An Air Source Heat Pump Water Heater (Heat Pump) from Steam Power is the go-to solution for readily available hot water. Our Heat Pump work even when the outside temperature is way less than zero degrees Celsius. They are energy efficient and save on fuel cost as the heat is absorbed from the atmosphere. Like every other product from Steam Power, the smallest detail has been looked at to make sure that only the best product reaches our valuable customer.

Steam Power heat pump water heaters are usually said to be "fit and forget" units. If you have bought a Steam Power heat pump water heater, rest assured, you have bought arguably the best product in its category with best in class features in safety, power saving and environment protection.

"Efficient Hot Water Solutions for Every Climate: Introducing Steam Power's Air Source Heat Pump Water Heater"

Inquiry Now
Features

A new technology CK-1 Ceramic coated inner tank ensures greater corrosion resistance against hard water.

Environmental friendly refrigerant: our heat pumps only use environment friendly R22 refrigerant.

Steam Power ASHPWHs provide constant temperature output ranging from 50-52 Degree Celsius.

Steam Power ASHPWHs come integrated with high pressure protection systems that ensures safety.

Lower Operating Cost

Environmental Friendly Refrigerant

Less Maintenance

Silent Operatoion

Features

Steam Power ASHPWHs operates on vast range of temperature variation ranging from -10 to 45 Degree Celsius.

Steam Power ASHPWHs comes equipped with a water resistant body. They are coated with an anti-corrosive coating that ensures long lasting maintenance free operation.

Our systems are easy to install and backed by hassle free service.

CK-1 Coated storage tank to perfectly suit all kinds of water.

Working Principle -Heat Pump Water Heater:

The heat pump makes use of a refrigerant for its operation. The low temperature refrigerant absorbs free heat from the atmospheric air in the evaporator is compressed by a highly efficient electrical compressor to a high- temperature and high-pressure vapour refrigerant.

This vapour is then passed through a heat exchanger (condenser) to transfer the heat to the water in the storage tank to produce hot water. The refrigerant then passes through an expansion valve and it goes back to the evaporator for absorbing the free heat from the atmospheric air again and the cycle is repeated.

"Efficient Heat Pump Operation: Harnessing Atmospheric Heat for Hot Water Production"

Inquiry Now

Warranty

Suitable For All Kinds of Water

Suits for Wide Range of Climatic Variations

CK-1 Ceramic Coated Inner Tank

Specification

Model SP-HP 300 SP-HP 500 SP-HP 750 SP-HP 1000 SP-HP 2000
Tank volume(L) 300 500 750 1000 2000
KW 3.5 5.2 7.0 10.5 17.5
Ton 1 1.5 2 3 5
Power Consumption Per Hour 2 units 3 units 4 units 7 units 10 units
Duration (at 28° Cold water) 2.5 hours 2.5 hour 2.5 hour 3.5 hour 4.5 hour
Production Capacity (LPH) 120 200 300 400 450
Backup electric heater (W) 1500 1500 1500 1500 1500
Power Supply 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz 220-240V/1/50Hz
Refrigerant R22 R22 R22 R22 R22
Max water temperature(°C) 52 52 52 52 52
Noise(db) ≤48 ≤48 ≤48 ≤48 ≤48
Inner tank Material CK-1 coated MS 5.0 mm CK-1 coated MS 5.0 mm CK-1 coated MS 5.0 mm CK-1 coated MS 5.0 mm CK-1 coated MS 5.0 mm
Water Inlet/outlet size 1" 1" 1" 1" 1"
Insulation thickness(mm) 70 70 70 70 70
Tank net weight(Kg) 130 130 130 130 130
Working temperature(°C) -10-45 -10-45 -10-45 -10-45 -10-45
Max. Operating Presure 5 kg 5 kg 5 kg 5 kg 5 kg

Condition: Heating Capacity at Ari 30°C to 35°C Water Temperature from 32°C/50°C

Heating Cost Comparison

Heating Load (Liters) 300L 500L 750L 1000L 2000L
Heat Pump Water Heater (Electricity) 35 53 70 172 315
Electric Geyser 65 110 163 216 435
Boiler 62 103 155 207 413
Gas Gyeser 78 130 195 260 520
Available Capacity

SP-HP 300
300Ltr.

SP-HP 500
500Ltr.

SP-HP 750
750Ltr.

SP-HP 1000
1000Ltr.

SP-HP 2000
2000Ltr.